CCSH240 | Specifications |
Automatic Chemistry Analyzer |
Analyze System |
Throughput | Maximun 240T/h |
Theory | Absorption spectronmetry,Transmission turbidimetry |
Methodology | End-point,Fixed-time,Kinetic,Monochromatic/bichromatic |
Test according set up,random access |
Reaction plate | Contain 81 reaction cuvettes |
Maximun reaction time | 15 minutes |
Minimum reaction volume | 150 ul |
Material of cuvettes | Special UV-transparent optical glass |
One-off cuvettes,can update to automatically cuvettes washing |
Optical System |
Light Source | Halogen-tungsten lamp |
Photometer | Reversed optics |
Wavelength | 340nm-900nm wavelength option |
Absorption | 0-4 Abs |
Reagent/Sample Handling |
Sample volume | 2-100 ul,step by 0.1 ul |
Sample plate | Contain60 sample positions |
Reagent/Sample Probe | Automatically checked,patent technology liquid level detection,collision protection Probe cleaning:Automatic washing for both inside and outside |
Samples cup | Support one-off blood cuvettes,micro cups,plastic cuvettes |
Reagent volume | 20-500 ul,step by 1 ul |
Reagent plate | Contain 20 reagent positions |
Sample/reagent probe | Collision protection liquid level detection;Internal and external probe washing;Probe depth adjustment automatically |
Reagent bottle | 15ml & 30ml; Dead volume less than 0.5 ml |
Temperature Control |
Maintenace free heater elements |
Temperature maintainance within 3 minutes |
Temperature of reagent compartment | 4-12℃ |
Reaction temperature | 37±0.1℃ |
Temperature fluctuation | ±0.1℃ |
Operation System |
Software | WindowsXP,2000 |
Database | SQL Server |
Data Storage | Automatic store & copy;No time and volumn limit;Lifetime preservation |
Print format | Can be set up,offer several standard format |
Calibration mode | Linear curce type:Single-point linear,two-point linear and multi-point linear none linear;Curve type:Logistic-Log 4P,Logistic-Log5p,Spline,index automatically use best calibration curve and standard |
QC Methods | Real time,within day & between day |
Quality Control Diagram | L-J,cumulative,twin plot |
Control software | Random set up,default westgard multi-rule |
Status display | Real time monitoring of reagent residual volume Running status of reagent tray,samples tray |
Adjustment | Dynamic and real time display of running status;Intelligent carry over settings to adjust test sequence;Original reaction data record;Detail profile of alert messages |
Setting | Operation permission setting,Item setting,cross polution setting,cuvette blank setting |
Others |
Water consumption | Less than 1 L per hour |
Power Supply | AC 220V±22V 50Hz±1Hz |
Frequency | Maximun 200VA |
Dimension | 720mm×581mm×545mm |
Weight | 60kg |
Accessory | Software |