| Main body | High-strength engineering plastic rack, light, beautiful and corrosion resistant
 | 
| Scope of application | adult, child | 
| Gas source | O2: 0.27~0.55MPa N2O: 0.27~0.55MPa | 
| Flow meter | O2: 0.1~10L/min   N2O: 0.1~10L/min | 
| O2, N2O linkage and N2O Stopper When using nitrous oxide, oxygen concentration>25%;
 When the oxygen pressure<0.2MPa, the flow of nitrous oxide would be cut off.
 | 
| Flow rate of rapid oxygen supply | 25~75L/min | 
| Low oxygen pressure alarm | There will be sound alarm when the oxygen pressure < 0.2MPa
 | 
| Vaporizer | It has the function of automatic compensation based on pressure, temperature, and flow rate.
 The regulation range of evaporator
 concentration is 0~5 vol%. Among
 Halothane, Enflurane, Isoflurane and
 Sevoflurane, one can be chosen for application
 as required by the customer. And vaporizers
 that are imported with original packaging are
 also available.
 | 
| Respiratory circuit | working mode: all-close, semi-close, semi-open releasing pressure: 0.5~7 kPa
 | 
| Respiratory bellows | bellows for adults, bellows for children tidal volume range:0~1,500 ml
 | 
| Ventilator | 
| Display mode | High-definition 5.7” LCD screen display | 
| Ventilation mode | IPPV, SIPPV, SIMV, PEE,MANUAL, SIGH | 
| Ventilation parameters | Tidal volume | 50~1500ml | 
| Rate | 2~99bmp | 
| SIMV rate | 2~20bpm | 
| I:E | 2:1~1:8 | 
| Inspiratory trigger pressure | -1.0~2.0 kPa | 
| PEEP | 0~2.0 kPa | 
| Pressure range | 1.0~6.0 kPa | 
| SIGH | 1.5 times the inspiratory time | 
| Parameters for ventilation monitoring tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure | 
| Monitoring of oxygen concentration | (21%~100%) | 
| Security Alarm System | 
| Oxygen Concentration alarm | upper limit setting range (50%~100%) | 
| low limit setting range (15%~50%) | 
| Airway pressure alarm | upper limit setting range 1.0~6.0 kPa | 
| low limit setting range   0.4~2.0 kPa | 
| Per-minute ventilation volume alarm | upper limit setting range 3.0~30L/min | 
| low limit setting range   1.0~10L/min | 
| Sustained high-pressure alarm | it will give alarm when stress have consistently been higher than 2.5 kPa
 | 
| Suffocation alarm | it will give sound and light alarm if there is no tidal volume input for 15 seconds
 | 
| Power alarm | 
| Power | AC 220V±10%     50Hz±1Hz (UPS, Storage battery)
 | 
| Items within brackets are optional. |