Products & Solutions
About Concern Support
Language
EN
Search Login
Home>
>
Product Information
CCZB-1800YMedical Syringe Pump CCZB-1800Y
  • CCZB-1800Y
Medical Syringe Pump CCZB-1800Y
Medical Syringe Pump CCZB-1800Y
Model:
CCZB-1800Y
Brand:
Concern
Price:
Inquiry
MOQ:
1
Ship From:
Guangzhou
Shipping:
15 days after payment
Payment Method

Related Products

Model: CC-01BI
Model: CC-01B2
Model: CC-850
Model: CC01-I
Model: CC01-II
Model: CC600P
Model: CC600M
Model: CC560B1
Model: CC560B1A
Model: CC560B2
Model: CC560B2A
Model: CC560B2B
  • Best Sallers
  • New Arrivals
  • Product detail
  • Shipping methods
  • Payment methods

Medical Syringe Pump CCZB-1800Y

Features:

1.      Compatible with syringes from (2/3ml), 5ml,10ml,20ml,30ml,50ml,60ml.

2.      Stackable to be the maximum 8 channels.

3.      High accuracy +/-2% after correct calibrated.

4.      Three work modes: Rate mode, Time mode and Weight mode.

5.      Bolus / Purge, KVO function.

6.      With drug libraries:17 categories of common drugs,1030 kinds of drug names in total.

7.      History recorded, real time displayed.

8.     12 hours continuous work after fully charged.


Technical Specifications

PARAMETER

SPECIFICATION

Applicable syringes

2/3ml, 5ml,10ml,20ml,30ml,50ml,60ml of any standard

Accuracy

+/- 2% with correct calibration

Rate mode

50ml(60ml):0.1ml/h-1800.0ml/h (0.1ml/h step)
20ml(30ml):0.1ml/h-800.0ml/h (0.1ml/h step)
10ml:0.1ml/h-400.0ml/h (0.1ml/h step)

5ml (2/3ml): 0.1~200ml/h (0.1ml/h step)

(Programmable 0.01ml/h~9999.9ml/h)

Time Mode

SOL. VOL:0.1-999.9ml (0.1ml step)
TIME:1-1999min (1min step)

Body Weight Mode:

Volume:0.1-999.9ml(0.1ml step)
DRUG MASS:0.1-999.9mg 0.1mg step)
DOSE:0.01-99.99ug/kg/min(0.01ug/kg/min step)
WEIGHT:0.1-300kg(0.1kgthe least step)

Total VolumeRange

0.1-1999.9ml (0.1 ml step)

Purge Rate

50ml(60ml):1800.0ml/h,

20ml(30ml):800.0ml/h,

10ml:400.0ml/h, 5ml (2/3ml): 200ml/h

Programmable and adjustable

KVO Rate

1ml/h

Occlusion pressure

Three level setting LOW, MEDIUM or HIGH

Alarms

Near empty, Syringe empty, Volume complete (when limit volume is set), Occlusion, Syringe loose, Operation error, Low battery, device failures.

Three levels of alarm volume LOW, MEDIUM or HIGH

Bolus Rate

5ml: 10~200ml/h,10ml:10-300ml/h,20ml(30ml):10-600ml/h,

50ml(60ml):10-1200ml/h

Programmable and adjustable

Bolus Volume

Maximum of 25ml

Interface

RS-232  (Reserved port)

Power source

AC power supply: AC 100 to 240V( +/-10%),50/60Hz;
Built-in LithiumBattery: Rechargeable, 11.1V, 2000mAh.

12 hours of continuous operation

Accessories:

AC power line, Operational manual

Protection Class

Class I, Type CF,IPX4

Dimension / Net weight

230mm*150mm*125mm,2.0kg


Write down your demand below and we will contact you within 24h!

Click Refresh
Submit
在线客服