Product Information
CCX-300300mA Medical X-ray
  • CCX-300
300mA Medical X-ray unit CCX-300
300mA Medical X-ray
Model:
CCX-300
Brand:
Concern
Price:
Inquiry
MOQ:
1
Ship From:
Guangzhou
Shipping:
15 days after payment
Payment Method

Related Products

Model: CC-01BI
Model: CC-01B2
Model: CC-850
Model: CC01-I
Model: CC01-II
Model: CC600P
Model: CC600M
Model: CC560B1
Model: CC560B1A
Model: CC560B2
Model: CC560B2A
Model: CC560B2B
  • Best Sallers
  • New Arrivals
  • Product detail
  • Shipping methods
  • Payment methods

300mA Medical x ray radiography equipment CCX-300    

                                                

Detail Specification:

●Single-table / Single-tube

●Rotary anode X-ray tube unit and tangential annular tube head

●Single-phase full wave rectification high-voltage generator

●Power voltage (V) radiograph kilovolt (KV). Step-less control electricmechanism

●Filament stabilizer for X-ray tube and space charge complementor

●Radiograph volume KV/mA and S. grading and interlock protection

● Adopt digitalcircuit timer. Grading according to R10 Priority coefficient. (For moreaccurately circuit of silicon-controlled rectifier of heavy power)

●Radiographic table can move in length and breadth.

● Theradiographic table, column and viblrating grid are in a whole without ceilingand floor rails bottom


Main Technical Indexes:

Item

Contents

Index

Demand of Power Supply

Capacity

Two-phase 30KVA

Voltage Frequency

380V/220V   50HZ

Internal Resistance

0.75Ω (380V)  0.25Ω(220V)

Power Supply

Adjustment Range

380% at 380V,

220V at 220V,being adjustable continuously

Radiograph

Voltage

50—125KV  being adjustable continuously

Current

Small Focus  50mA  100mA

Big Focus  50mA 100mA 200mA 300mA

Time

0.04 - 6.35s  23grades together, according to R10 Coefficient

HT Generator

Capacity

20KVA(Instantaneous)

Max DC Output Voltage

125KV

Max DC Output Currency

300mA

X-ray Tube

Model

XD51. 20—40 / 125

Focus

Small Focus 1*1 mm    Big Focus 2*2 mm

Radiographic Table

Length*Width*Height of Bed Surface

2000mm*665mm*700mm

Moving range of bed surface

640mm in Length,  200mm in breadth

Ray-filter of bed

Travel in Length≥500mm

Grid Density  N=28

Convergence Distance :f­ =100cm

Grid Ratio: r=8

Column of X-ray Tube Unit

Moving Longitudinally along Radiographic Table

1000mm  or  1800mm

Distance to ground as moving up and down (along column)

650 - 1800mm

Rotary around the center of cross arm

180 degree

Rotary around the shaft line of X-ray Annular Tubes

-10 degree -  -60 degree -  +120 degree

Max Size of Cassette

356mm * 432mm (14’’ x 17 ‘’)

 