USE
General radiography, Filter-ray-filter radiography.


Unit Configuration  
Control, HT generator unit, Ht cable, X-ray tube unit, Radiographic table-X-ray source column, Collimator.  


Function

This photography x ray can used for general radiography, Bucky radiography of body's head, chest, foot and hand, bones in lying.


Feature of x-ray machine:
1. meter-indicating.
2. single-table single tube.
3. single-phase, full wave rectification
4. stationary anode x-ray tube assembly.
5. X-ray tube filament s voltage regulator, space charge compensator .
6. Radiograph plain table wimple structure and easy assembling.


Min Technical Indexes

Item

Contents

Index

Demand of power supply

Capacity

Two-phase 30KVA

Voltage, Frequency

380V/220V   ±10%50HZ ±0.5Hz

Intemal resistance

2Ω(380V)  0.6  Ω(220V)

power supply

Adjustable range

380±10% at220V being adjustable continuously

Radiograph

Voltage

50-90KV

Current

Small focus: 15mA,Big focus:30mA 60mA 100mA

Time

0.04~6.35s 23grades together grading a according to R10 coefficient

High-voltage generator

Capacity

7KVA

Max DC output voltage

90KV

Max DC output current

100mA

X-Ray tube

Model

0XD4-2.9/100

Focus

Small focus 1.8×1.8mm  big focus4.3×4.3mm

Radiographic table

Length×width×height of bed surface

2000mm×665mm×700mm

Moving range of bed surface

640mm in Length,200mm in breadth

Ray-filter of table

Travel in length ≥50mm

Grid density N=28

Convergence distance f.=100cm

Grid ratio r=8

Column of X-ray tube unit

Moving Longitudinally along

1000mm or 1800mm

Radiographic table

Distance to friend as moving up and down (along column)

650~1800mm

Rotary around the center of cross arm

±180°

Rotary around the shaft line of X-ray annular tubes

  -10~60~+120°

Max size of cassette

356mm×432mm(14″×17″)