| CCL-C240 | Specifications |
| Automatic Chemistry Analyzer |
| Analyze System |
| Throughput | Maximun 240T/h |
| Theory | Absorption spectronmetry,Transmission turbidimetry |
| Methodology | End-point,Fixed-time,Kinetic,Monochromatic/bichromatic |
| Test according set up,random access |
| Reaction plate | Contain 81 reaction cuvettes |
| Maximun reaction time | 15 minutes |
| Minimum reaction volume | 150 ul |
| Material of cuvettes | Special UV-transparent optical glass |
| One-off cuvettes,can update to automatically cuvettes washing |
| Optical System |
| Light Source | Halogen-tungsten lamp |
| Photometer | Reversed optics |
| Wavelength | 340nm-900nm wavelength option |
| Absorption | 0-4 Abs |
| Reagent/Sample Handling |
| Sample volume | 2-100 ul,step by 0.1 ul |
| Sample plate | Contain60 sample positions |
| Reagent/Sample Probe | Automatically checked,patent technology liquid level detection,collision protection Probe cleaning:Automatic washing for both inside and outside |
| Samples cup | Support one-off blood cuvettes,micro cups,plastic cuvettes |
| Reagent volume | 20-500 ul,step by 1 ul |
| Reagent plate | Contain 20 reagent positions |
| Sample/reagent probe | Collision protection liquid level detection;Internal and external probe washing;Probe depth adjustment automatically |
| Reagent bottle | 15ml & 30ml; Dead volume less than 0.5 ml |
| Temperature Control |
| Maintenace free heater elements |
| Temperature maintainance within 3 minutes |
| Temperature of reagent compartment | 4-12℃ |
| Reaction temperature | 37±0.1℃ |
| Temperature fluctuation | ±0.1℃ |
| Operation System |
| Software | WindowsXP,2000 |
| Database | SQL Server |
| Data Storage | Automatic store & copy;No time and volumn limit;Lifetime preservation |
| Print format | Can be set up,offer several standard format |
| Calibration mode | Linear curce type:Single-point linear,two-point linear and multi-point linear none linear;Curve type:Logistic-Log 4P,Logistic-Log5p,Spline,index automatically use best calibration curve and standard |
| QC Methods | Real time,within day & between day |
| Quality Control Diagram | L-J,cumulative,twin plot |
| Control software | Random set up,default westgard multi-rule |
| Status display | Real time monitoring of reagent residual volume Running status of reagent tray,samples tray |
| Adjustment | Dynamic and real time display of running status;Intelligent carry over settings to adjust test sequence;Original reaction data record;Detail profile of alert messages |
| Setting | Operation permission setting,Item setting,cross polution setting,cuvette blank setting |
| Others |
| Water consumption | Less than 1 L per hour |
| Power Supply | AC 220V±22V 50Hz±1Hz |
| Frequency | Maximun 200VA |
| Dimension | 720mm×581mm×545mm |
| Weight | 60kg |
| Accessory | Software |