CCBT-1001. Two temperature control modes: Air mode and Baby mode controlled by micro-computer; 2. Use AC Power and DC Power alternatively, DC 12V or DC 24V Power on the ambulance;
  • CCBT-100
Hospital Baby Infant Transport Incubator CCBT-100
1. Two temperature control modes: Air mode and Baby mode controlled by micro-computer; 2. Use AC Power and DC Power alternatively, DC 12V or DC 24V Power on the ambulance;
Model:
CCBT-100
Brand:
Concern
Price:
Inquiry
MOQ:
1
Ship From:
Guangzhou
Shipping:
15 days after payment
Payment Method

Related Products

Model: CC-01BI
Model: CC-01B2
Model: CC-850
Model: CC01-I
Model: CC01-II
Model: CC600P
Model: CC600M
Model: CC560B1
Model: CC560B1A
Model: CC560B2
Model: CC560B2A
Model: CC560B2B
  • Best Sallers
  • New Arrivals
  • Product detail
  • Shipping methods
  • Payment methods

Hospital Baby Infant Transport Incubator CCBT-100

Infant Transport Incubator Brief Introduction

1. Two temperature control modes: Air mode and Baby mode controlled by micro-computer;

2. Use AC Power and DC Power alternatively, DC 12V or DC 24V Power on the ambulance;

3. Set temperature, air temperature, baby temperature and internal battery voltage can be displayed separately;

4. Failure alarm indication;

5. >37°C temperature set function is optional;

6. Disposable skin temperature sensor is optional;

7. Double wall acrylic glass hood with side door, the bassinet can be pulled out from the side door;

8. Humidify by natural air flow;

9. The height of whole unit can be adjusted;

10. Oxygen supply system;

11. Observation lamp;

12. Two types of trolley can be chosen: common trolley and ambulance type trolley.



Infant Transport Incubator Standard Configuration

Main body (including the hood, controller, bassinet, internal battery, and observation lamp), oxygen cylinders, oxygen supply system, skin temperature sensor, I.V. Pole, mattress, trolley.


Optional configuration: >37°C override temperature mode, extra internal battery, ambulance type trolley, disposable skin temperature sensor.


Infant Transport Incubator Specification

1. AC Power supply: AC220V-230V/50Hz Or AC110-120V/50-60Hz

2. DC Power supply:

3. DC12V/10A or DC24V/6A

4. Input power: 400VA

5. Mode of control: Air mode and baby mode controlled by micro-computer

6. Air temperature control range: 25°C-37°C(Override mode 37-38°C)

7. Baby temperature control range: 34°C-37°C(Override mode 37-37.5°C)

8. Accuracy of skin temperature sensor: ≤0.3°C

9. Temperature variability: ≤1.0°C

10. Temperature uniformity: ≤1.5°C(mattress is on the horizontal position)

11. Noise inside hood: ≤52dB(A) (Environment noise≤45dB(A))


12. Failure alarm: over-temperature alarm, temperature deviation alarm, sensor alarm, motor fan failed alarm, power failure alarm and so on.

13. Operating at temperature equilibrium:90min(Set Temp 36°C-Ambient 15°C)


Infant Transport Incubator Environmental Temperature

Operating range: 10 °C-30°C

(Set temperature should be higher 3°C than the environment temperature)

Ambient air movement rate: ≤1.0m/s