CCX-200200ma x-ray for all body parts checking
  • CCX-200
200mA Medical X-ray unit CCX-200
200ma x-ray for all body parts checking
Model:
CCX-200
Brand:
Concern
Price:
Inquiry
MOQ:
1
Ship From:
Guangzhou
Shipping:
15 days after payment
Payment Method

Related Products

Model: CC-01BI
Model: CC-01B2
Model: CC-850
Model: CC01-I
Model: CC01-II
Model: CC600P
Model: CC600M
Model: CC560B1
Model: CC560B1A
Model: CC560B2
Model: CC560B2A
Model: CC560B2B
  • Best Sallers
  • New Arrivals
  • Product detail
  • Shipping methods
  • Payment methods

200mA Medical X-ray unit CCX-200


USE: General radiography, Filter-ray-filter radiograph

Unit Configuration 
Control, HT generator unit, Ht cable, X-ray tube unit, Radiographic table-X-ray source column, Collimator

Function
The unit can used for general radiography, Bucky radiography of body’s head, chest, foot and hand, bones in lying

Feature
1. meter-indicating
2. single-table single tube
3. single-phase, full wave rectification
4. stationary anode x-ray tube assembly
5. X-ray tube filament s voltage regulator, space charge compensator
6. Radiograph plain table wimple structure and easy assembling

MAIN TECHNICAL INDEXES

ITEMCONTENTSINDEX
Demand of power supplyCapacityTwo-phase 30KVA
Voltage Frequency380V/220V   ±10%50HZ ±0.5Hz
Intemal resistance0.75Ω(380V)0.25Ω(220V)
power supplyAdjustable range380±10% at220V being adjustable continuously
RadiographVoltage50-100KV  being  adjustable  continuously
currentSmall focus:50mA100mA,   Big focus:50Ma 100mA  200mA  300mA
time0.04~6.35s 23grades together grading a according to R10 coefficient
High-voltage generatorCapacity20KVA(instantaneous)
Max DC output voltage100KV
Max DC output current200mA
X-Ray tubeModelXD51.20-40/100
FocusSmall focus 1×1mm  big focus2×2mm
Radiographic tableLength*width*height of bed surface2000mm×665mm700mm
Moving range of bed surface640mmin Length,200mmin breadth
Ray-filter of tableTravel in length ≥500mm
Grid density N=28
Convergence distance f。=100cm
Grid ratio r=8
Column of X-ray tube unitMoving Longitudinally along Radiographic table1000mmor 1800mm
Distance to friend as moving up and down (along column)650~1800mm
Rotary around the center of cross arm±180°
Rotary around the shaft line of X-ray annular tubes-10°~60°~  +120°
Max size of cassette356mm×432mm(14×17)

Note: We will make another notice if the contour of product and technical parameters will be changed
Net Weight:                 Gross: 695             Packing Size: 230*112*111

Net Weight:                 Gross: 695             Packing Size: 230*112*111